1. Check the water filter regularly;
2. If there is dust on the machine, use dry compressed air to clean the machine carefully, but turn off the main power supply;
Fault: before inspection, be sure to turn off the main power supply, because there are thousands of volts to tens of thousands of volts in the machine.
Phenomenon 1: common red light (overload light)
reason:
A) The insulation of the lower mold is damaged;
B) Dirt, dust and water in working objects, vibrating cylinders or upper and lower molds need to be cleaned;
C) Poor horizontal position of upper and lower molds;
D) The upper and lower molds have no insulation, but directly touch each other;
E) Input power is too high;
F) The vacuum tube is damaged or loose;
G) The electronic board of over-power protection is damaged, and the over-current protection board is the one with three main electrical appliances;
H) The coherer is too large and the output is too high;
1) The working load is too large to exceed the rated output of the same machine;
J) Failure of temperature control part;
K) High voltage capacitor is damaged;
50) The insulating column (upper formwork) is damaged.
Phenomenon 2: during high cycle output, the main power supply is disconnected or the fuse is blown
1. Check the water filter regularly;
2. If there is dust on the machine, use dry compressed air to clean the machine carefully, but turn off the main power supply;
Fault: before inspection, be sure to turn off the main power supply, because there are thousands of volts to tens of thousands of volts in the machine.
Phenomenon 1: common red light (overload light)
reason:
A) The insulation of the lower mold is damaged;
B) Dirt, dust and water in working objects, vibrating cylinders or upper and lower molds need to be cleaned;
C) Poor horizontal position of upper and lower molds;
D) The upper and lower molds have no insulation, but directly touch each other;
E) Input power is too high;
F) The vacuum tube is damaged or loose;
G) The electronic board of over-power protection is damaged, and the over-current protection board is the one with three main electrical appliances;
H) The coherer is too large and the output is too high;
1) The working load is too large to exceed the rated output of the same machine;
J) Failure of temperature control part;
K) High voltage capacitor is damaged;
50) The insulating column (upper formwork) is damaged.
Phenomenon 2: during high cycle output, the main power supply is disconnected or the fuse is blown
Service hotline: